Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550089

ABSTRACT

Abstract: The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.


Resumo O objetivo deste estudo foi avaliar a estabilidade de implante e a microarquitetura óssea em duas técnicas de fresagem, comparando a técnica convencional (CT) e a osseodensificação (OD) (Versah Burs - Jackson - Mississippi - EUA). O torque de inserção do implante (IT), quociente de estabilidade primária (ISQ) e a estrutura trabecular peri-implantar foram avaliados em fragmentos ósseos obtidos de tíbia de porco (n=12), divididos entre CT (n=6) e OD (n=6). Após o procedimento de fresagem, foram instalados implantes (3,5x8,5 mm, Epikut - SIN - São Paulo - Brasil). O IT e o ISQ foram aferidos por meio de um torquimetro digital e análise de frequência de ressonância. Em seguida, os fragmentos ósseos contendo os implantes foram removidos com trefina e analisados ​​por microtomografia computadorizada (µCT, 8,0 µm). A comparação entre os grupos foi realizada por meio do teste-t não-pareado (α=0.05). Os resultados revelaram que a OD promove maior torque de inserção (CT: 7,67 ± 2,44º Ncm; OD: 19,78 ± 5,26 Ncm) (p=0,0005), embora a estabilidade primária não tenha sido diferente (CT: 61.33 ± 4.66; OD:63.25 ± 4.58) (p=0,48). Houve um aumento significativo no volume ósseo peri-implantar (CT: 23,17±3,39 mm3; OD: 32,01±5,75 mm3) (p=0,0089) e parâmetros trabeculares: separação (CT: 0,4357 ± 0,03 mm; OD: 0,3865 ± 0,04 mm) (p=0,0449), número (CT: 1,626 ± 0,18 1/mm; OD: 1,946 ± 0,13 1/mm) (p=0,007) e espessura (CT: 0,1130 ± 0,009 mm; OD: 0,1328 ± 0,015 mm) (p=0,02) O índice de modelo estrutural (SMI) não demostrou diferença estatisticamente significativa (p=0.1228). Concluindo, OD apresenta maiores valores de torque de inserção e promove mudanças benéficas na microarquitetura óssea em comparação com a TC, revelando maior volume ósseo peri-implantar.

2.
Pesqui. bras. odontopediatria clín. integr ; 23: e210162, 2023. tab, graf
Article in English | LILACS, BBO | ID: biblio-1431047

ABSTRACT

ABSTRACT Objective: To compare the agreement of images in white light (WL), fluorescence (FL), and digital radiographs (DR), on the diagnosis and treatment decisions for occlusal caries lesions against a micro-CT gold standard. Material and Methods: Ten extracted third molars, with enamel and/or dentin caries (ICDAS 2-4), were included. Occlusal surface images were acquired with an intraoral camera (SoproLife®) in WL and FL modes. DR was obtained using an intraoral X-ray and a semi-direct digital system. A total of 780 images were needed, organized in a template, to be later examined by twenty-six dentists invited to compose the study. The Generalized Estimation Equations model was used to compare the proportions of the correct answers between the three methods and the gold standard. When significant, Bonferroni post-hoc test was used to identify differences (α=5%). Results: Most of the examiners were specialists (76.9%) with 14.5 years of experience. All diagnostic methods were similar and showed low agreement (DR 12.7%, WL 16.5%, and FL 16.5%) compared with gold standard caries diagnostic scores. Regarding treatment decisions, mean agreement for all diagnostic methods was higher (43.2%; p<0.001), and among all methods, WL (48.1%) and FL (51.2%) modes performed better than DR (30.4%, p<0.001). Conclusion: SoproLife® images could help clinicians to propose rational, minimally invasive treatments for occlusal caries lesions.


Subject(s)
Humans , Dental Caries/diagnostic imaging , X-Ray Microtomography/methods , Fluorescence , Clinical Decision-Making , Molar, Third/injuries , Effectiveness , In Vitro Techniques/methods , Cross-Sectional Studies/methods , Radiography, Dental, Digital/methods
3.
Pesqui. bras. odontopediatria clín. integr ; 22: e210112, 2022. tab, graf
Article in English | LILACS, BBO | ID: biblio-1386810

ABSTRACT

Abstract Objective: To evaluate the efficacy of silver diamine fluoride (SDF) in arresting dentin caries lesions when applied under different concentrations and times. Material and Methods: Forty-two bovine blocks were selected and fixed in 24-well plates. Each well received a mixed bacterial inoculum added to the culture medium with 5% sucrose. The plates were incubated in microaerophilia (7 days) for caries formation, confirmed by micro-CT (M1). SDF was applied over the carious lesions for different times and concentrations (n=6): SDF 30% - immediate removal, 1 minute and 3 minutes; SDF 38%, - immediate removal, 1 minute and 3 minutes. The group without treatment was the control. Then, the samples were again scanned by micro-CT (M2) and submitted to a second cariogenic challenge for 21 days. Then, a final scan was performed (M3). Results: Mean pH at the culture medium and lesion depth were compared using Kruskal-Wallis and Wilcoxon tests. 38% SDF showed the lowest metabolic activity of the biofilm. All 38% groups and 30% 1 and 3 minutes did not show an increase in mean lesion depth comparing M3 with M1. However, only 30% 3 minutes and 38% 1 and 3 minutes showed a significant reduction of lesion depth. Conclusion: The minimum application time of 30% SDF to arrest dentin caries lesion was 1 minute, while 38% SDF arrested with application and immediate removal.


Subject(s)
Animals , Cattle , Tooth Remineralization , Cariostatic Agents/therapeutic use , Dental Caries/epidemiology , Dentin , Diamines/chemistry , Fluorides/chemistry , Silver/therapeutic use , In Vitro Techniques/methods , Longitudinal Studies , Statistics, Nonparametric , Biofilms , X-Ray Microtomography/instrumentation
4.
Braz. j. oral sci ; 20: e210432, jan.-dez. 2021. ilus
Article in English | BBO, LILACS | ID: biblio-1254269

ABSTRACT

Aim: The aim of this study was to evaluate, by micro-computed tomography (micro-CT) analysis, the remaining filling material during endodontic retreatment performed with Protaper retreatment without solvent. Methods: Forty mandibular molars were divided into two groups (n = 20) according to the sealer used in the obturation: the bioceramic TotalFill BC (TF) or the resin-based AH Plus (AHP). The specimens were scanned before instrumentation, after obturation and after filling removal. Only the mesial roots were analysed. The filling volumes and the remaining filling material were calculated in the entire root canal and in the cervical, middle and apical thirds. Results: The volume of obturation and the volume of remaining filling material in the entire root canal and in the cervical, middle and apical thirds of the canal between the groups were not statistically different (independent t-test, p > 0.05). In the AHP group, there was a higher percentage of remaining filling material in the middle third than in the cervical third (p < 0.05). Conclusion: The filling material could not be entirely removed from any specimen


Subject(s)
Root Canal Filling Materials , Retreatment , X-Ray Microtomography , Molar
5.
Braz. dent. j ; 32(4): 62-73, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345511

ABSTRACT

Abstract This study aimed to evaluate the in vitro effect of a single application of experimental nanocomposite solutions on the prevention of dental caries around orthodontic brackets. The specimens were exposed to mesoporous silica (MS) nanocomposites containing fluoride by association with titanium tetrafluoride (TiF4) or sodium fluoride (NaF). Nanocomposites also could contain calcium and groups were described as MSCaTiF4, MSTiF4, MSCaNaF, MSNaF, and controls (TiF4, and NaF). Specimens were subjected to the formation of a multispecies biofilm to generate a cariogenic challenge. After 24h, both pH and total soluble fluoride concentration of the culture medium were assessed. Mineral loss was evaluated by percentage of surface mineral loss (%SML), mineral volume variation (ΔZ) of inner enamel and polarized light microscopy (PL). Linear (Ra) and volumetric (Sa) surface roughness and scanning electronic microscopy (SEM) were used to assess enamel topography. Statistical analyses were conducted considering p<0.05. MSNaF had the highest value of culture medium pH after cariogenic challenge, similarly to MSTiF4. All nanocomposite solutions released less fluoride than their controls NaF and TiF4 (p<0.05). All nanocomposite solutions presented lower %SML compared to their respective control groups (p<0.05). Lower Ra, Sa and ΔZ were observed for experimental groups compared to TiF4 (p<0.05). The results were confirmed by PL and SEM analysis. The experimental nanocomposite solutions contributed for lower enamel demineralization around orthodontic brackets.


RESUMO Este estudo teve como objetivo avaliar o efeito in vitro de uma única aplicação de soluções experimentais de nanocompósitos na prevenção de cárie dentária em braquetes ortodônticos. Os espécimes foram expostos a nanocompósitos de sílica mesoporosa (MS) contendo fluoreto por associação com tetrafluoreto de titânio (TiF4) ou fluoreto de sódio (NaF). Os nanocompósitos também podem conter cálcio e os grupos foram descritos como MSCaTiF4, MSTiF4, MSCaNaF, MSNaF e controles (TiF4 e NaF). Os espécimes foram submetidos à formação de um biofilme multiespécie para gerar um desafio cariogênico. Após 24h, o pH e a concentração de flúor solúvel total do meio de cultura foram avaliados. A perda mineral foi avaliada pela porcentagem de perda mineral superficial (% SML), variação do volume mineral (ΔZ) do esmalte interno e microscopia de luz polarizada (PL). A rugosidade superficial linear (Ra) e volumétrica (Sa) e a microscopia eletrônica de varredura (MEV) foram utilizadas para avaliar a topografia do esmalte. As análises estatísticas foram realizadas considerando p <0,05. MSNaF apresentou o maior valor de pH do meio de cultura após o desafio cariogênico, semelhante ao MSTiF4. Todas as soluções de nanocompósitos liberaram menos flúor do que seus controles NaF e TiF4 (p <0,05). Todas as soluções de nanocompósitos apresentaram% SML menor em comparação com seus respectivos grupos de controle (p <0,05). Ra, Sa e ΔZ menores foram observados para os grupos experimentais em comparação ao TiF4 (p <0,05). Os resultados foram confirmados por análises PL e SEM. As soluções experimentais de nanocompósitos contribuíram para a menor desmineralização do esmalte ao redor dos braquetes ortodônticos.


Subject(s)
Humans , Tooth Demineralization , Orthodontic Brackets , Dental Caries/prevention & control , Nanocomposites , Sodium Fluoride , Titanium , Cariostatic Agents , Dental Enamel , Fluorides
6.
Radiol. bras ; 53(3): 161-166, May-June 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136063

ABSTRACT

Abstract Objective: To evaluate and reconstruct three-dimensional images of vascularization along the fallopian tube (FT), as well as to determine its relationship with the ovary and ovarian fimbria, and to quantify the blood vessels along the FT according to its anatomical segments, using confocal microtomography (micro-CT). Materials and Methods: Nine specimens (six FTs and three FTs with ovaries) were fixed in a solution of 10% formalin for > 24 h at room temperature. Iodine staining was performed by soaking the specimens in 10% Lugol's solution for 24 h. All specimens were evaluated using micro-CT. A morphometric analysis was performed on the reconstructed images to quantify the vascular distribution along the FT. Results: In the FTs evaluated, the density of blood vessels was significantly greater in the fimbrial segments than in the isthmic segments (p < 0.05). The ovarian fimbria was clearly identified, demonstrating the important relationship between these vessels and the FT fimbriae. Conclusion: We believe that the vascularization in the fimbriae is greater than and disproportional that in the other segments of FT, and that the ovarian fimbria plays an important role in the development of that difference.


Resumo Objetivo: Avaliar e reconstruir imagens tridimensionais da vascularização ao longo da trompa de Falópio (TF) e sua relação com o ovário e fímbria do ovário, além de quantificar os vasos sanguíneos ao longo da TF de acordo com seus segmentos anatômicos usando microtomografia confocal (micro-TC). Materiais e Métodos: Nove espécimes (seis com TFs e três com TFs e ovários) foram fixados em solução de formol a 10% por mais de 24 h à temperatura ambiente. A coloração com iodo foi realizada usando solução de Lugol a 10% durante 24 h. Todos os espécimes foram avaliados usando micro-TC. Uma análise morfométrica foi realizada nas imagens reconstruídas para quantificar a distribuição vascular ao longo da TF. Resultados: A densidade dos vasos sanguíneos nas fímbrias foi significativamente aumentada em comparação ao segmento ístmico da TF (p < 0,05). A fímbria ovariana foi claramente identificada, demonstrando importante relação entre esses vasos e as fímbrias da TF. Conclusão: Acreditamos que as fímbrias apresentam vascularização aumentada e desproporcional em comparação com os demais segmentos da TF e que a fímbria ovariana desempenha importante papel nessa diferença.

8.
Pesqui. bras. odontopediatria clín. integr ; 20: e5114, 2020. tab, graf
Article in English | BBO, LILACS | ID: biblio-1135522

ABSTRACT

Abstract Objective: To compare the immediate microleakage of carious fissures sealed with a caries infiltrant covered by a flowable composite or solely with a flowable composite. Material and Methods: Extracted carious molars (n=20) were selected and paired among the experimental groups according to caries progression scores. Experimental groups (n=10) were divided according to the following sealing techniques: 1) caries infiltrant (Icon) + flowable composite (Z350 flow); 2) flowable composite (Z350 flow). Specimens were immersed in 3% methylene blue and evaluated in a stereomicroscope. Microleakage scores were attributed independently by two calibrated evaluators and the mode value was considered as the mean for the specimen. Binomial tests were used to test differences between two independent sample proportions at 5% significance level. Results: In the flowable composite group, a higher prevalence of dye penetration along the full depth of the fissure was observed, compared with caries infiltrant + flowable composite (p<0.05). For specimens showing dye penetration up to half of the fissure, in caries infiltrant + flowable composite group, all specimens showed dye penetration into the sealant, but not over the infiltrant. Conclusion: Using caries infiltrant as sealing material under a flowable composite cover is effective to improve the immediate sealing ability in carious fissures compared to sealing with flowable composite.


Subject(s)
Humans , Pit and Fissure Sealants/chemistry , Dental Caries/prevention & control , Dental Leakage/diagnostic imaging , Dental Materials/chemistry , Molar , Brazil , Methylene Blue
9.
Braz. j. oral sci ; 18: e191627, jan.-dez. 2019. ilus
Article in English | LILACS, BBO | ID: biblio-1095362

ABSTRACT

Aim: The purpose of this study was to compare root canal volumes (RCVs) obtained by means of cone beam computed tomography (CBCT) to those obtained by micro-computed tomography (micro-CT) after applying different segmentation algorithms. Methods: Eighteen extracted human teeth with sound root canals were individually scanned in CBCT and micro-CT using specific acquisition parameters. Two different images segmentation strategies were applied to both acquisition methods (a visual and an automatic threshold). From each segmented tooth, the root canal volume was obtained. A paired t-test was used to identify differences between mean values resulted from the experimental groups and the gold standard. In addition, Pearson correlation coefficients and the agreement among the experimental groups with the gold standard were also calculated. The significance level adopted was 5%. Results: No statistical differences between the segmentation methods (visual and automatic) were observed for micro-CT acquired images. However, significant differences for the two segmentation methods tested were seen when CBCT acquired images were compared with the micro-CT automatic segmentation methods used. In general, an overestimation of the values in the visual method were observed while an underestimation was observed with the automatic segmentation algorithm. Conclusion: Cone beam computed tomography images acquired with parameters used in the present study resulted in low agreement with root canal volumes obtained with a micro-CT tomography gold standard method of RCV calculation


Subject(s)
Root Canal Therapy , Imaging, Three-Dimensional , Cone-Beam Computed Tomography , X-Ray Microtomography
10.
Braz. dent. j ; 29(6): 530-535, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-974189

ABSTRACT

Abstract In order to evaluate the volume of dentinal cracks taking into account the age of the dentin and the type of file system used for endodontic procedures, forty freshly extracted single-rooted lower incisive teeth presenting similar root volume, were divided into two groups according to the age of the patient: Group Young (18 - 30 years old) and Group Old (60 years old or more). Each specimen was scanned by microcomputed tomography (micro-CT) in three stages: (i) before any treatment, (ii) after endodontic treatment with Reciproc files (REC), and (iii) after subsequent endodontic retreatment. Each group was subdivided into two subgroups, according to the retreatment technique used: retreatment with REC or with ProTaper Universal Retreatment (PUR) files. For each subgroup, the images were analyzed for differences in the volume of dentinal cracks in the middle and apical thirds of the teeth , according to the dentin age. In both stages (before and after instrumentation), the micro-CT images of the old root dentin presented with higher volume of cracks than those of the young root dentin, statistical significance notwithstanding (p>0.01). The use of REC files appeared to have no statistically significant differences in the generation of cracks in any type of root dentin when compared with PUR files (p>0.01). When retreated with PUR, the old root dentin presented with a significantly higher volume of cracks (p<0.01) when compared with the old root dentin initially.


Resumo Para avaliar o volume de fissuras dentinárias levando em consideração a idade da dentina e o tipo de sistema de limas utilizadas para procedimentos endodônticos, 40 dentes unirradiculares, incisivos inferiores, apresentando similar volume radicular, recentemente extraídos foram divididos em dois grupos de acordo com a idade do paciente: Grupo Jovem (18 a 30 anos) e Grupo Idoso (60 anos ou mais). Cada espécime foi scaneada por microtomografia computadorizada (micro-CT) em três estágios: (i) antes de qualquer tratamento, (ii) após tratamento endodôntico com limas Reciproc (REC) e (iii) após subsequente retratamento endodôntico. Cada grupo foi subdividido em dois subgrupos, de acordo com a técnica de retratamento utilizada: retratamento com REC ou com lima ProTaper Universal Retreatment (PUR). As imagens foram analisadas quanto às diferenças no volume das fissuras dentinárias nos terços médio e apical dos dentes de acordo com a idade da dentina. Em ambos os estágios (antes e depois da instrumentação), as imagens de micro-CT da dentina radicular idosa apresentaram maior volume de trincas do que as jovens, sem significância estatística (p>0.01). O uso das limas REC mostram não ter diferença estatística significante na geração de fissuras, em qualquer tipo de dentina, quando comparadas às limas PUR (p>0.01). Quando retratada com PUR, a dentina radicular idosa apresentou um volume de trincas significativamente maior (p<0.01) quando comparado com a dentina radicular idosa inicialmente.


Subject(s)
Humans , Adolescent , Adult , Middle Aged , Tooth Fractures/diagnostic imaging , Root Canal Preparation/methods , Dentin/injuries , Dentin/diagnostic imaging , In Vitro Techniques , Age Factors , Retreatment , X-Ray Microtomography
11.
Braz. oral res. (Online) ; 32: e60, 2018. tab, graf
Article in English | LILACS | ID: biblio-952138

ABSTRACT

Abstract The aim of this study was to check the in vitro accuracy of ICDAS criteria on digital images compared to visual examination for the diagnosis of occlusal caries against a micro-CT gold standard. ICDAS was scored in 40 extracted permanent molars by means of visual inspection and stereomicroscopic images. Visual examinations were performed in duplicate and at a one-week interval by three different calibrated examiners. The analysis of digital images by ICDAS criteria was also performed in duplicate, 1 month after visual examinations. The detection methods were compared by means of sensitivity, specificity, area under the curve, predictive positive and negative values, and accuracy for two different thresholds (1- sound vs. carious teeth; 2- tooth requiring operative vs. non-operative treatment). Sensitivity and accuracy values for threshold 1 in the visual ICDAS and image-based ICDAS methods were high for sensitivity (0.93 and 0.97) and for accuracy (0.83 and 0.85), but low for specificity (0.55 for both methods). Specificity values for threshold 2 were 0.77 and 0.82, while sensitivity was 0.33 and 0.28 for each method. Spearman's rank correlation coefficient was 0.53 and 0.43 (p<0.05) for visual and image-based ICDAS compared to the gold standard scores. Both visual and image-based ICDAS scores were similar to each other in terms of diagnostic accuracy when compared to the micro-CT gold standard. Low specificity for the presence of caries and sensitivity for the detection of caries requiring operative treatment were found.


Subject(s)
Humans , Dental Caries/diagnostic imaging , X-Ray Microtomography/methods , Reference Values , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Statistics, Nonparametric , Dental Caries/pathology , Dental Enamel/pathology , Dental Enamel/diagnostic imaging , Dentin/pathology , Dentin/diagnostic imaging
12.
Braz. dent. j ; 27(6): 664-669, Nov.-Dec. 2016. graf
Article in English | LILACS | ID: biblio-828066

ABSTRACT

Abstract This study aimed to evaluate the cause-effect relationship between canal preparation with ProTaper Universal (PTU) system and dentinal defects formation using micro-computed tomography (micro-CT) analysis. Forty mesial canals of mandibular molars with a type II Vertucci's canal configuration were scanned at an isotropic resolution of 14.16 µm. The sample was assigned to an experimental (n = 30) and a control (n = 10) groups, and the mesial canals were prepared with PTU system up to F2 instrument. The specimens from the experimental group were scanned and the cross-section images of the mesial roots, before and after preparation, were screened to identify the presence of dentinal defects. In the control group, the specimens were sectioned perpendicularly to the long axis of the root into 1-mm-thick slices (n = 80) and examined under optical microscope. Once a dentinal defect was detected, the slice was scanned through micro-CT. In the experimental group, dentinal micro-cracks were observed in 4,828 slices (24.04%). In all cross-section images, dentinal defects identified in the postoperative images were already present in the corresponding preoperative image. In the control group, 13 out of 80 slices (16.25%) had at least one dentinal defect visualized under stereomicroscopy, which was identified after a further micro-CT scanning. Micro-CT showed reliability as similar as optical microscopy in detecting dentinal defects, adding the possibility of tracking the dentinal tissue, before and after canal preparation, and providing a clear visualization of micro-cracks. Root canal preparation with PTU system did not induce the formation of new dentinal defects.


Resumo O objetivo deste estudo foi avaliar a relação de causa-efeito entre o preparo do canal radicular com o sistema ProTaper Universal (PTU) e a formação de defeitos dentinários usando a análise por micro-tomografia computadorizada (micro-CT). Quarenta raízes mesiais de molares inferiores com a configuração tipo II de Vertucci foram escaneadas com resolução isotrópica de 14.16 μm. A amostra foi distribuída em um grupo experimental (n = 30) e um grupo controle (n = 10), e os canais mesiais foram preparados com o sistema PTU até a lima F2. As amostras do grupo experimental foram escaneadas e as imagens de secção transversal das raízes mesiais, antes e após o preparo, foram analisadas ​​para identificar a presença de defeitos dentinários. No grupo controle, os dentes foram seccionados perpendicularmente em relação ao longo eixo da raiz em fatias de 1 mm de espessura (n = 80) e examinados ao microscópio óptico. Uma vez detectado um defeito dentinário, a fatia foi escaneada através da micro-CT. No grupo experimental, defeitos dentinários foram observados em 4.828 secções transversais (24,04%). Em todas as imagens de secção transversal, os defeitos dentinários após os procedimentos experimentais já estavam presentes na secção pré-operatória correspondente. No grupo controle, 13 das 80 fatias (16,25%) apresentaram pelo menos um defeito dentinário visualizado através do microscópio, o qual foi identificado em um escaneamento posterior. A micro-CT mostrou confiabilidade com a microscopia óptica para detecção e visualização dos defeitos dentinários, permitindo acompanhar o tecido dentinário antes e depois do preparo do canal. O preparo do canal radicular com o sistema PTU não induziu a formação de novos defeitos dentinários.


Subject(s)
Humans , Dentin , Root Canal Preparation/methods , Causality , X-Ray Microtomography
13.
Braz. dent. j ; 26(6): 624-629, Nov.-Dec. 2015. graf
Article in English | LILACS | ID: lil-769560

ABSTRACT

The aim of this study was to compare the percentage of non-instrumented area of root canals prepared with different enlargements using single-file reciprocating systems (Reciproc and WaveOne) and a conventional multi-file rotary (BioRaCe) system by micro-computed tomographic analysis. Thirty mesial roots of mandibular molars with moderate curvature (10° to 20°) presenting a type II Vertucci canal configuration and similar internal volume were chosen and scanned at an isotropic resolution of 14.16 µm. The sample was assigned to 3 groups (n=10) according to the system used for root canal preparation: Reciproc, WaveOne, and BioRaCe groups. Second and third scans were taken after the canals were prepared with instruments sizes 25 and 40, respectively. The recorded images of the surface area voxels of the canals, before and after preparation were examined from the furcation level to the apex to quantify the non-instrumented surface. Statistical data were compared using GLM for repeated-measures with a significance level set at 5%. Instrumentation systems did not influence the percentage of untouched root canal surfaces (p=0.690) whilst a significant reduction in the percentage of static voxels was observed after the enlargement of the root canal (p=0.010) in all groups (p=0.507). None of the systems was able to prepare the entire surface area of the mesial root canal of mandibular molars. The increased final apical size resulted in a significant positive effect on the shaping ability of the tested systems.


Resumo O objetivo deste estudo foi comparar a porcentagem de área não-instrumentada de canais radiculares preparados com diferentes ampliações utilizando sistemas reciprocantes de lima única (Reciproc e WaveOne) e um sistema rotatório convencional de múltiplas limas (BioRaCe) usando a análise da micro tomografia computadorizada. Trinta raízes mesiais de molares inferiores com curvatura moderada (10º a 20º) apresentando a configuração classe II de Vertucci e semelhança de volume do canal foram selecionadas e escaneadas em uma resolução isotrópica de 14,16 µm. A amostra foi dividida em 3 grupos (n=10) de acordo com o sistema utilizado para a preparação do canal radicular: grupo Reciproc, grupo WaveOne e grupo BioRaCe. Segundo e terceiro escaneamentos foram realizados após os canais serem preparados com instrumentos tamanhos 25 e 40, respectivamente. As imagens registradas de voxels da área de superfície dos canais, antes e após o preparo, foram examinadas desde o nível da furca até o ápice para quantificar a superfície não instrumentada. Os dados foram comparados estatisticamente através de GLM para medidas repetidas com um nível de significância de 5%. Os sistemas de instrumentação não influenciaram o percentual de superfícies não tocadas dos canais radiculares (p=0,690), enquanto que uma redução significativa no percentual de voxels estáticos foi observada após o alargamento do canal radicular (p=0,010) em todos os grupos (p=0,507). Nenhum dos sistemas foi capaz de preparar toda a área de superfície do canal mesial dos molares inferiores. O aumento do tamanho final apical resultou num efeito positivo significativo sobre a capacidade de modelar dos sistemas testados.


Subject(s)
Humans , Alloys , Root Canal Preparation , X-Ray Microtomography/methods
14.
Acta cir. bras ; 27(3): 217-222, Mar. 2012. ilus
Article in English | LILACS | ID: lil-617960

ABSTRACT

PURPOSE: To verify the effects of tibolone administration on trabecular and cortical bone of ovariectomized female rats by computed radiography system (CRS). METHODS: The experiment was performed on two groups of rats previously ovariectomized, one received tibolone (OVX+T) while the other did not (OVX), those groups were compared to a control group (C) not ovariectomized. Tibolone administration (1mg/day) began thirty days after the ovariectomy and the treatment remained for five months. At last, the animals were euthanized and femurs and tibias collected. Computed radiographies of the bones were obtained and the digital images were used to determine the bone optical density and cortical thickness on every group. All results were statistically evaluated with significance set at P<0.05 percent. RESULTS: Tibolone administration was shown to be beneficial only in the densitometric analysis of the femoral head, performing higher optical density compared to OVX. No difference was found in cortical bone thickness. CONCLUSION: Ovariectomy caused bone loss in the analyzed regions and tibolone administered in high doses over a long period showed not to be fully beneficial, but preserved bone mass in the femoral head.


OBJETIVO: Verificar o efeito da administração de tibolona no tecido ósseo cortical e trabecular de ratas castradas através de radiografia computadorizada. MÉTODOS: O experimento foi realizado em dois grupos de ratas previamente ooforectomizadas, onde um grupo recebeu tibolona (OVX+T) e o outro não (OVX). Esses grupos foram comparados a um grupo controle (C) não ooforectomizado. A administração de tibolona (1mg/dia) começou trinta dias após a ooforectomia e o tratamento teve duração de cinco meses. No final, os animais foram mortos e fêmures e tibias coletados. As radiografias computadorizadas dos ossos foram obtidas e as imagens digitais usadas para determinar a densidade óssea e a espessura cortical em todos os grupos. Todos os resultados foram avaliados estatisticamente com significância estabelecida a 5 por cento. RESULTADOS: A administração de tibolona mostrou ser benéfica apenas para análise densitométrica da cabeça do fêmur, apresentando maiores valores de densidade comparada ao grupo OVX. Nenhuma diferença significativa foi encontrada para espessura óssea cortical. CONCLUSÃO: A ooforectomia ocasionou perda óssea nas regiões analisadas e a tibolona administrada, em dose elevada e durante um longo período, mostrou não ser totalmente benéfica, porém preservou a massa óssea na cabeça femoral.


Subject(s)
Animals , Female , Rats , Bone Density/drug effects , Estrogen Receptor Modulators/adverse effects , Estrogens/deficiency , Femur , Norpregnenes/adverse effects , Ovariectomy/adverse effects , Tibia , Disease Models, Animal , Epidemiologic Methods , Estrogen Receptor Modulators/administration & dosage , Femur/drug effects , Femur/pathology , Image Processing, Computer-Assisted , Norpregnenes/administration & dosage , Rats, Wistar , Tibia/drug effects , Tibia/pathology
15.
Hig. aliment ; 22(160): 89-92, abr. 2008. tab
Article in Portuguese | LILACS | ID: lil-531974

ABSTRACT

Amostras de mel puro de floradas silvestres, de mesma origem, foram irradiadas em Irradiador Gamma Cell, 220, Nordion, no LIN/COPPE/URFJ, com fonte gama de 60°C. O mel foi distribuído em potes de polietileno, de 400 g e irradiado com as doses de 5KGy, 10 KGy, 15 KGy e 25 KGy, à temperatura de 20°C, RJ.C. Potes de mel não-irradiados foram separados para controle. As amostras foram submetidas às análises físico-químicas de: acidez livre, açúcares redutores, coloração, índice de HMF, insolúveis, Ph, sacarose aparente, umidade, odor e atividade diastásica, recomendadas pela SND/Ministério da Agricultura (LA-NARA), conforme as normas do CAC e AOAC. Os resultados mostraram que mesmo para a dose mais elevada (25 KGy), as alterações foram muito pequenas. Apenas a coloração foi mais alterada, mudando para um âmbar ligeiramente mais claro. Na análise sensorial usou-se a escala hedônica de 7 pontos, com participação de 30 consumidores escolhidos aleatoriamente. A análise estatística dos resultados foi feita pela Análise de Variança (ANOVA) e o Teste de Tukey ao nível de 1 por cento, para as preferências entre os atributos dos grupos. As diferentes doses de radiação não produziram diferenças significativas no aroma e no sabor, mas apenas na cor. Comparando com a amostra não-irradiada, as irradiadas diferiram 0,05 por cento na cor, 0,2 por cento no sabor e 0,02 por cento no aroma.


Subject(s)
Food Analysis , Food Irradiation , Honey
16.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.495-496, tab, graf.
Monography in Portuguese | LILACS | ID: lil-233836

ABSTRACT

Desenvolveu-se uma metodologia de estimativa de dose na superfície de entrada do paciente, em procedimentos de radiodiagnóstico por videofluoroscopia, analisando a imagem do sinal de vídeo. Os resultados foram gerados a partir da análise de imagens gravadas em um equipamento de raios X, Siemens Polymat 50, e posteriormente digitalizadas. Os resultados indicam ser possível o uso da imagem obtida através do sinal de vídeo, como indicador da dose na superfície de entrada de um corpo em tempo real.


Subject(s)
Fluoroscopy/instrumentation , Dosimetry/instrumentation , Radiation Dosage , Television/instrumentation , Calibration
SELECTION OF CITATIONS
SEARCH DETAIL